LDP1602 LCD Module
LCD display module for E2000 and R2000 series I/O
|
|
- Hot-pluggable display module for ioLogik
- Active Ethernet I/O and Serial Remote I/O servers
- Easy, portable configuration kit for IP display and configuration
- Direct display for analog value and digital input, counter status
- No battery required (powered by I/O server)

|
|
ioLogik E2262
Active Ethernet I/O with 8 thermocouple inputs and 4 digital outputs
|
|
- Supports J, K, T, E, R, S, B, and N type thermocouple and mV modes
- Conversion Time: Less than 90ms
- Instant event messaging by TCP/UDP/e-mail/SNMP Trap
- PC-based configuration utility and web console
- Easy-to-use Click&Go™ Logic for local output control
- Windows/WinCE VB/VC and Linux C API
- I/O control over Modbus/TCP and SNMP protocol
- NIST traceable calibration

|
|
ioLogik E2260
Active Ethernet I/O with 6 RTD inputs and 4 digital outputs
|
|
- Supports PT, JPT, Ni RTD sensor types and resistors
- Adjustable RTD sampling rate
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- PC-based configuration utility and web console
- Easy-to-use Click&Go™ Logic for local output control
- Windows/WinCE VB/VC and Linux C API
- I/O control over Modbus/TCP and SNMP protocol
- NIST traceable calibration

|
|
ioLogik E2214
Active Ethernet I/O with 6 digital inputs and 6 relay outputs
|
|
- 6 DIs supporting PNP, NPN, and Dry contact
- 6 Form A relay output (Normal Open)
- Relay specification: 5A/250 VAC, 5A/30 VDC
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- DI and Relay counter saving when power off
- PC-based configuration utility and web console
- Power On default relay status setting with sequence
- Easy-to-use Click&Go™ Logic for local output control
- Windows/WinCE VB/VC and Linux C API
- I/O control over Modbus/TCP and SNMP protocol

|
|
ioLogik E2212
Active Ethernet I/O with 8 digital inputs, 8 digital outputs, and 4 configurable DIO
|
|
- Selectable digital I/O combination by software
- Accepts PNP or NPN sensors
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- Easy-to-use Click&Go™ Logic for local output control
- PC-based configuration utility and web console
- I/O control over Modbus/TCP and SNMP protocol
- Windows/WinCE VB/VC and Linux C API
- Peer-to-Peer I/O without controller

|
|
ioLogik E2210
Active Ethernet I/O with 12 digital inputs and 8 digital outputs
|
|
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- DI counter saving when power off
- Easy-to-use Click&Go™ Logic for local output control
- 12-point 24 VDC digital input with counter
- 8-point 24 VDC digital output with pulse output
- PC-based configuration utility and web console
- I/O control over Modbus/TCP and SNMP protocol
- Windows/WinCE VB/VC and Linux C API
- Peer-to-Peer I/O without controller

|
|
ioLogik E2240
Active Ethernet I/O with 8 analog inputs and 2 analog outputs
|
|
- Instant event messaging by TCP/UDP/e-mail/SNMP trap
- Easy-to-use Click&Go™ Logic for local output control
- 8-channel analog inputs for voltage, current signal
- 2-channel analog outputs for voltage, current actuator control
- PC-based configuration utility and web console
- Windows/WinCE VB/VC and Linux C API
- I/O control over Modbus/TCP and SNMP protocol
- NIST-traceable calibration

|
|
ioLogik E2242
Active Ethernet I/O with 4 analog inputs and 12 configurable DIO
|
|
- 4 fixed differential analog input channels
- 12 configurable digital input/output channels
- Instant event messaging by TCP, UDP, e-mail, SNMP Trap
- PC-based configuration utility and web console
- Easy-to-use Click&Go™ Logic for local output control
- I/O control over Modbus/TCP and SNMP protocol
- NIST traceable calibration

|
|