Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

moxa_banner
Ethernet Micro RTU Controller
LDP1602 LCD Module
LCD display module for E2000 and R2000 series I/O


  • Hot-pluggable display module for ioLogik
  • Active Ethernet I/O and Serial Remote I/O servers
  • Easy, portable configuration kit for IP display and configuration
  • Direct display for analog value and digital input, counter status
  • No battery required (powered by I/O server)


ioLogik E2262
Active Ethernet I/O with 8 thermocouple inputs and 4 digital outputs


  • Supports J, K, T, E, R, S, B, and N type thermocouple and mV modes
  • Conversion Time: Less than 90ms
  • Instant event messaging by TCP/UDP/e-mail/SNMP Trap
  • PC-based configuration utility and web console
  • Easy-to-use Click&Go™ Logic for local output control
  • Windows/WinCE VB/VC and Linux C API
  • I/O control over Modbus/TCP and SNMP protocol
  • NIST traceable calibration


ioLogik E2260
Active Ethernet I/O with 6 RTD inputs and 4 digital outputs


  • Supports PT, JPT, Ni RTD sensor types and resistors
  • Adjustable RTD sampling rate
  • Instant event messaging by TCP/UDP/e-mail/SNMP trap
  • PC-based configuration utility and web console
  • Easy-to-use Click&Go™ Logic for local output control
  • Windows/WinCE VB/VC and Linux C API
  • I/O control over Modbus/TCP and SNMP protocol
  • NIST traceable calibration


ioLogik E2214
Active Ethernet I/O with 6 digital inputs and 6 relay outputs


  • 6 DIs supporting PNP, NPN, and Dry contact
  • 6 Form A relay output (Normal Open)
  • Relay specification: 5A/250 VAC, 5A/30 VDC
  • Instant event messaging by TCP/UDP/e-mail/SNMP trap
  • DI and Relay counter saving when power off
  • PC-based configuration utility and web console
  • Power On default relay status setting with sequence
  • Easy-to-use Click&Go™ Logic for local output control
  • Windows/WinCE VB/VC and Linux C API
  • I/O control over Modbus/TCP and SNMP protocol
     

ioLogik E2212
Active Ethernet I/O with 8 digital inputs, 8 digital outputs, and 4 configurable DIO


  • Selectable digital I/O combination by software
  • Accepts PNP or NPN sensors
  • Instant event messaging by TCP/UDP/e-mail/SNMP trap
  • Easy-to-use Click&Go™ Logic for local output control
  • PC-based configuration utility and web console
  • I/O control over Modbus/TCP and SNMP protocol
  • Windows/WinCE VB/VC and Linux C API
  • Peer-to-Peer I/O without controller


ioLogik E2210
Active Ethernet I/O with 12 digital inputs and 8 digital outputs


  • Instant event messaging by TCP/UDP/e-mail/SNMP trap
  • DI counter saving when power off
  • Easy-to-use Click&Go™ Logic for local output control
  • 12-point 24 VDC digital input with counter
  • 8-point 24 VDC digital output with pulse output
  • PC-based configuration utility and web console
  • I/O control over Modbus/TCP and SNMP protocol
  • Windows/WinCE VB/VC and Linux C API
  • Peer-to-Peer I/O without controller


ioLogik E2240
Active Ethernet I/O with 8 analog inputs and 2 analog outputs


  • Instant event messaging by TCP/UDP/e-mail/SNMP trap
  • Easy-to-use Click&Go™ Logic for local output control
  • 8-channel analog inputs for voltage, current signal
  • 2-channel analog outputs for voltage, current actuator control
  • PC-based configuration utility and web console
  • Windows/WinCE VB/VC and Linux C API
  • I/O control over Modbus/TCP and SNMP protocol
  • NIST-traceable calibration


ioLogik E2242
Active Ethernet I/O with 4 analog inputs and 12 configurable DIO


  • 4 fixed differential analog input channels
  • 12 configurable digital input/output channels
  • Instant event messaging by TCP, UDP, e-mail, SNMP Trap
  • PC-based configuration utility and web console
  • Easy-to-use Click&Go™ Logic for local output control
  • I/O control over Modbus/TCP and SNMP protocol
  • NIST traceable calibration